Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Flat panel detector |
1. Detector type: TFT whole board amorphous silicon flat panel detector |
2. Detector panel size: 430mm x 430mm |
3. Effective imaging size of detector: 17 × 17 inches; |
4. Pixel matrix collected by the detector: ≥ 3072 × 3072; |
5. Pixel spacing of detector: ≤ 146 μ m; |
6. Detector spatial resolution: 3.7LP/MM; |
7. Pixel grayscale: 17Bit; |
8. Image acquisition and transmission time: 3 seconds; |
High frequency and high voltage generator |
1. Maximum output power: 50kW; |
2. Input power supply: 380VAC three-phase |
3. Output voltage: 40-150kV; |
4. Tube current range: 10-630mA; |
5. Exposure time range: 1ms-10000ms |
5. Exposure time range: 1ms-10000ms |
6. mAs range: 0.1mAs-1000mAs; |
7. Support AEC and APR automatic exposure; |
8. Fault self diagnosis and display; |
X-ray tube assembly |
1. Focus design: 0.6mm/1.5mm |
2. Nominal electrical power: 22kW/54kW (50Hz); |
3. Maximum KV: 150kV |
4. Anode target angle: 12 ° |
Framework |
1. The lateral movement range of the overhead rail hanger shall not be less than 2400 mm |
The center lifting height of the column detector should be between 500mm and 1600mm, with a deviation of no more than ± 5%; |
2. The rotation angle of the column detector should be 0 °~90 °, and the deviation should not exceed ± 1% °;; |
3. The horizontal stroke of the X-ray tube component shall not be less than 2000 mm |
4.The lifting range of X-ray tube components should be 1400 mm, and the deviation should not exceed ± 5%. |
5. Rotation angle of X-ray tube components: 0 °~90 °, deviation should not exceed ± 1% ° |
Mobile bed |
The height of the bed surface from the ground should be 690mm, with a deviation of ± 50mm; |
2. The length of the bed surface should be 2000mm, the width should be 630mm, and the deviation should be ± 50mm; 3. The locking method should be mechanical locking, with a braking force of ≥ 100N; |
Filter grid and beam limiter |
1. Grid material: aluminum based grid; |
2. Size: 18 x 18 inches (48 x 48cm) |
3. The grid ratio of the filter wire grid is 10:1 |
4. Wire/inch: 215C; |
5. Focal length of filter grid: 1000MM; |
6. Special beam limiter with light field and multi blade DR |
Image acquisition/processing and diagnostic workstation software functions |
1. Chinese interface, standard DICOM3.0 image; |
2. Image acquisition workstation functions: adjust or preset window width/level, local automatic window width/level, preset window width/level, positive and negative image flipping, image flipping, rotation, image enlargement and roaming, image interpolation edge enhancement, local enlargement, restoration of original image annotation, text/number annotation, image annotation, ruler line segment measurement, square/circular measurement, arbitrary shape measurement, angle measurement automatic electronic cutting, image stitching, exposure index acquisition and display. |
3. Specialized image acquisition control software package, specialized part protocol processing software package; |
4. It has patient management, image acquisition, image processing (image correction, image flipping, USM sharpening, image filtering), image observation (providing image observation tools, measurement tools), and image stitching; |
5. Image printing: DICOM printing, paper printing, manual selection and printing of displayed images, single key selection and marking of image printing, selection of different printing devices, film formats and number of prints, print queue control, stop/start pre settings; |
6. User personalization settings: |
Display format and layout, default value settings, toolbar settings, part protocol enhancement filters; |
7. Image display: The display configuration supports 1920 × 1080 and high-definition display. |
Workstation |
1. CPU: Intel i5, above 3GHz; |
2. Host memory: ≥ 8GB DDR3 1600 high-speed memory; |
3. Hard drive: high-capacity high-speed hard drive 1T/7200rpm; |
4. Workstation monitor: 24 "IPS LCD monitor; |
5. Communication network card and network interface: 1000M network card, 1000M network interface, Jumbo Frame: 9K; |
6. DICOM3.0 interface; |
7.Windows 10 64 bit SP1 (Professional Edition or higher) |