Customization: | Available |
---|---|
Classification: | Human |
Type: | Aed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Type: 8-inch high-resolution LCD
Sweep Speed: 25mm/sec
Information Displayed: Heart Rate (HR), Lead/Pads status, On/Off Alarm, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy
Waveform: Biphasic
Charge Time: Less than 7 seconds with a new, fully charged battery
Energy Display: Both selected and delivered energy displayed on the monitor
Charge Prompts: Voice and visual prompts
Electrode Impedance Measurement Range: 0-250 ohms
Patient Connection: 5-lead or 3-lead ECG cable, paddles
Lead Selection: I, II, III, AVR, AVL, AVF, V
ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV
Heart Rate Range: 20-300 BPM
Heart Rate Alarm: User-selectable, displayed on monitor
Smart Alarms: Beeper/voice prompts for shockable rhythms
Paper Type: 50mm thermal
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec (user-selectable)
Printing Method: High-resolution thermal print head
Print-out Modes: Manual or automatic (user-configurable)
On/Off Control: Front panel and paddle
Automatic Function: 9-second recording initiated by alarm activation, defibrillator charge, or discharge
Type: Rechargeable Ni-MH, 12V
Operating Time:
60 defibrillator discharges at maximum energy
3 hours minimum of continuous ECG monitoring
Additional Parameters: Operating time varies with different functions
Function: Auto analyze and charge X3 with programmable auto energy level selection, screen prompts, and voice prompts
Shockable Rhythms: Ventricular fibrillation (amplitude >=200µV), ventricular tachycardia (rates >=140bpm), QRS complex wave duration >=140ms
Charge Control: Device front panel or paddle key
Prompts: Voice and visual prompts
Energy Selection: 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules
Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave ("SYNC" message displayed on monitor)
Type: VVI
Pulse Type: Rectangular, constant current
Pulse Amplitude: 0 to 180 mA ± 10% or 5 mA (whichever is greater)
Pacing Rate: 30 ppm to 180 ppm ±1.5% (increments/decrements by 2 ppm)
Multi-Function Electrode (MFE) Pads: Multipurpose defibrillation/pacing electrodes
Pause: Pacing pulse frequency reduced by a factor of 4 when activated
Pulse Width: 20 ± 1.5 ms
Output Protection: Fully defibrillator protected and isolated
Type of Sensor: Sidestream
Technical Principle: Non-dispersive infrared gas analysis (NDIR)
Storage Conditions: -40°C to 70°C, <90% RH, non-condensing
Operating Conditions: 5°C to 50°C, 10 to 90% RH, non-condensing
Ambient Pressure: 55-115 kPa
Power Supply: 5 V ±5% (max ripple 200 mVp-p)
TDP: Typical value 120mA, Excursion calibration typical value 280mA
Range: 0-19.7% (0-150 mmHg or 0-20 kPa)
Resolution: 0.1 mmHg
Accuracy:
0 - 40 mmHg ± 2 mmHg
41 - 70 mmHg ± 5% of reading
71 - 100 mmHg ± 8% of reading
101 - 150 mmHg ± 10% of reading
Respiratory Rate:
Measurement Range: 2-150 BPM
Accuracy: 1% ±1 BPM
Measurement Technology: Oscillometric
Parameters Displayed: Systolic, diastolic, and mean pressure
Measurement Mode: Manual, Auto, and Sequence (Adult Mode)
Resolution: 1 mmHg
NIBP Range & Accuracy:
Systolic Pressure: 0 kPa ~ 34 kPa (0 mmHg ~ 255 mmHg); Accuracy: ±0.5 kPa (±4 mmHg)
Diastolic Pressure: 2 kPa ~ 26 kPa (15 mmHg ~ 195 mmHg); Accuracy: ±0.5 kPa (±4 mmHg)
Mean Blood Pressure: 2.67 kPa ~ 31.3 kPa (20 mmHg ~ 235 mmHg); Accuracy: ±0.5 kPa (±4 mmHg)
Pressure Accuracy: ±0.5 kPa (±4 mmHg)
Pressure Range: 0 kPa (0 mmHg) ~ 40 kPa (300 mmHg)
Alarm Range:
Systolic Pressure: 0 kPa ~ 40 kPa (0 mmHg ~ 300 mmHg)
Diastolic Pressure: 0 kPa ~ 26.7 kPa (0 mmHg ~ 200 mmHg)
Mean Blood Pressure: 0 kPa ~ 40.0 kPa (0 mmHg ~ 300 mmHg)
Alarm Accuracy: Not exceeding the set value ±10%
Alarm Time: No more than 12 seconds
Measurement Range: 30% ~ 100%
±2% between 80% ~ 90%
±5% for other ranges
Alarm Range: User-set high and low limits
Alarm Accuracy: ±10% within setting values
Alarm Time Accuracy: Less than 12 seconds
Battery/Level Indicator: Real-time battery monitoring
Internal Thermal Printer: 50mm integrated thermal recorder
Paddle: Easy charging and shocking operation via buttons
Biphasic Technology: Impedance compensation for more effective defibrillation with less energy and reduced heart damage
Data Storage: 65 hours of all measured parameters
Quick Conversion: Easily switch from adult to pediatric mode by removing the outer surface
We are a medical equipment company based in Guangdong, China, established in 2023. Our products are sold worldwide, including:
With a team of 301-500 employees, we are dedicated to delivering high-quality products and services globally.
We specialize in providing a wide range of medical equipment, including:
We aim to make your experience seamless and professional, with flexible payment options and reliable delivery services.