Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | X Ray Equipment |
Still deciding? Get samples of US$ 10000/Set
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
A mammogram is an advanced, specialized low-dose X-ray imaging technique, expertly crafted for capturing detailed images of the breast. It serves as an essential and powerful tool in the early detection and diagnosis of any abnormal lumps or masses within breast tissue. This method is celebrated as one of the most effective means for the early identification of breast cancer. Detecting breast cancer at an early stage significantly boosts the chances of successful treatment, often culminating in a complete cure when the malignancy is addressed in its earliest phase.
Item | Parameter | Remark |
X-ray Generator | Generator Type: High Frequency Inverter 80kHz | Self-developed and world advanced all-solid-state high frequency high voltage x-ray generator |
Input Power: Single phase 220VAC, 50/60Hz | ||
Radiographic Ratings: | ||
Large Focal Point 20-35kV/10-510mAs | ||
Small Focal Point 20-35kV/10-100mAs | ||
Power Rating: 6.2kVA | ||
X-ray Tube | Focal Spot Size: Dual Focus 0.1 / 0.3mm | Model:IAE TUBE FROM ITALY |
Target Material: Molybdenum (Mo) | ||
Port Material: Beryllium (Be) | ||
High-speed anode drive: 2800 /10000rpm | ||
Target angle: 10°/16° | ||
Anode Heat Storage: 210kJ (300kHU) | ||
Anode Cooling: Air cooling | ||
Filtration: Mo(0.03mm), Al(0.5mm) | ||
Radiographic Stand | C-ARM: Vertical Movement: 590mm | Electric Isocentric rotating |
Center of electric rotating C-arm | ||
Automatic return function by one key | ||
Rotations Degree: +90°~-90° | ||
Automatically released after the exposure pressure settings display | ||
Compression flexible, stepless speed. | ||
Max. pressure: 200N | ||
Max. travel: 150mm | ||
SID: 650mm | ||
Flat Panel Detector | Detector material: Amorphous silicon | China Flat Panel Detector |
Effective coverage of detector: 24x30cm | 24x30cm | |
Pixel matrix: 3072x1944 | as standard | |
Limit of spatial resolution: 6.0Lp/mm | ||
DQE value: 70% | ||
dynamic range: 14bit digital output | ||
pixel size: 75μm | ||
High voltage Synchronizer trigger: BNC | ||
Output: Camera Link or Ethernet | ||
Working condition: 10ºC-40ºC | ||
storage environment: -10ºC-50ºC | ||
Bucky housing and movement device | Size: 374*304*65mm | |
Stepless speed regulating range: 0~6cm/s | ||
Movement range: 0.5~2cm | ||
Grid Size: 24x30cm | ||
Grid ratio: 5:1 | ||
Grid density: 30lp/cm | ||
Focal distance: 650mm | ||
Image acquisition workstation | CPU≥Intel Core Duo 2.60GHz | Configuration including Diagnose digital workstation |
Hardware≥250G high speed Hardware | ||
Memory≥2G | 5M medical monitor for optional | |
Display card≥512MB | ||
high brightness high-contrast LCD,1280*1024 Pixel resolution | ||
Network interface Work-list | ||
DICOM3.0 transmission | ||
100/1000 Gigabit Ethernet | ||
Software | ||
Imaging software package DMOC V1.0 | ||
Others | Line Voltage | 110V for optional |
220V ac±10% 25A,Single phase |
Yes, most of our products have the CE certificate.