Customization: | Available |
---|---|
Classification: | Imaging Diagnostic Equipment |
Type: | Ultrasound Scanner |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Product Name: Full Digital Color Doppler Veterinary Ultrasound Scanner | |
1.1 Structure Style: Trolley type, single screen | |
2.2. Application: | |
2.1 It's applicable for animals' examination and diagnosis on digestive system, reproductive system, urinary | |
system for animal hospitals and scientific institutions. | |
3. System technical specifications and summary: | |
3.1 Operating System: Windows 10 | |
3.2 Pulsed Wave Doppler Imaging (PW) | |
3.3 Directional Power Doppler Imaging (DPDI) | |
3.4 Real-time Triplex | |
3.5 Spatial Compound Imaging | |
3.6 Tissue Harmonic Imaging (THI) | |
3.7 2B/4B Imaging Modes | |
3.8 Support Language: Chinese, English, French, Russian, Spanish | |
3.9 Monitor Size: ≥21.5 inch | |
3.10 All-in-one clipboard: saved images will display on the bottom of the screen, which can be directly | |
transferred or deleted. | |
3.11 The system has the function of on-the-spot upgrade. | |
3.12 Presettable Conditions: Preset optimal image inspection conditions to reduce adjustment during | |
operation. | |
3.13 Probe interface: 2 | |
3.14 Trapezoidal Imaging | |
3.15 One Key Smart Optimization | |
4. Probe: | |
4.1 Convex probe (detecting depth: 30-255mm) | |
Fundamental Frequency: 2.0MHz/2.5MHz/3.0MHz//3.5MHz/4.0MHz/5.5MHz | |
Harmonic Frequency: H4.0MHz/H5.0MHz | |
4.2 Linear probe (detecting depth: 20-128mm) | |
Fundamental Frequency: 6.0MHz/7.5MHz/8.5MHz/10.0MHz/12.0MHz | |
Harmonic Frequency: H10.0MHz | |
4.3 Micro-convex probe R11 (detecting depth: 30-111mm) | |
Fundamental Frequency: 4.5MHz/5.0MHz/6.0MHz/6.5MHz/7.0MHz/9.0MHz | |
Harmonic Frequency: H8.0MHz | |
4.4 Rectal probe (detecting depth: 20-111mm) | |
Fundamental Frequency: 4.0MHz/6.5MHz/9.0MHz | |
Harmonic Frequency: H8.0MHz | |
5. 2D Imaging Mode | |
5.1 Gain: 0-100, Step 1 adjustable | |
5.2 TGC: 8 segment adjustable | |
5.3 Dynamic: 20-280, 20 levels adjustable | |
5.4 Pseudo color: 0-11, adjustable | |
5.5 Sound power: 5%-100%, step 5% adjustable | |
5.6 Body mark: ≥18 kinds optional | |
5.7 Maximum focus: ≥6, which can be moved throughout the whole process | |
5.8 Grey scale map: 0-7, 7 levels adjustable | |
5.9 Filter: 0-4 | |
5.10 Scanning range: 50%-100% | |
5.11 Frame correlation: 0-4, 4 level adjustable | |
5.12 The screen has real-time display of sound power, probe frequency, dynamic range, pseudo color, gray | |
scale and other 14 parameters can be adjusted. | |
5.13 Line density: low, middle, high, 3 levels adjustable | |
5.14 Noise reduction: 0-14 | |
6. Color Doppler Imaging Mode | |
6.1 Color Frame correlation: 0-12, 12 levels adjustable | |
6.2 Color map: 0-7, 7 levels adjustable | |
6.3 Color flip: adjustable | |
6.4 B / C real-time split screen mode | |
6.5 Base line: 11 levels, adjustable | |
6.6 Line density: low, high, 2 levels adjustable | |
6.7 Filter: 0-5 levels adjustable | |
7. Spectral Doppler Imaging Mode | |
7.1 Sampling volume angle correction: -80°~80°adjustable | |
7.2 Sample volume: 0.5mm-20mm adjustable | |
7.3 Frequency: 2.5MHz, 3.0MHz | |
7.4 Base line: 9 levels, adjustable | |
7.5 Pseudo color: 0-5 | |
7.6 Parameter display: ≥4 kinds, adjustable | |
7.7 Speed scale: 32.8-328cm/s (different probes have different ranges) | |
7.8 Spectrum envelope function: real-time automatic spectrum envelope, manual spectrum envelope, and | |
other. The system automatically analyses and displays various data such as PS, ED, RI, PI, S/D, HR, etc. | |
7.9 Grey map: 0-7 | |
7.10 Filter: 0-20 | |
7.11 Dynamic range: 10-95db, step 5 | |
7.12 Noise reduction: 0-10 | |
7.13 Sound volume: 0-100 | |
8. Measurement and Analysis | |
8.1 General measurement: distance, area, angle, time, slope, heart rate, speed, acceleration, blood flow path, | |
blood flow spectrum trace, resistance index/pulsation index, etc | |
8.2 Professional OBC data package for different animals, such as Cannine, Feline, Equine, Bovine, Ovine | |
8.3 Measurement line: color and type can be adjusted at will (including the activation color and the | |
completion color) | |
8.4 Measurement result: display position and font size can be adjusted as needed | |
8.5 Professional data package: Abdomen, OBC, Urology, etc | |
9. Graphic and Text Management System | |
9.1 Host build in 256G hard disk, start fast and stable | |
9.2 Movie playback: ≥600 frames | |
9.3 Internal file information management system: can record patient number, name, check number, check | |
date and so on, and can be searched and managed by number, check number, name and so on. | |
9.4 Report type: ≥6, picture proof provided | |
9.5 One key fast report graphic and text management | |
9.6 Image format: BMP, DCM, JPG | |
9.7 With DICOM3.0 protocol, can be connected to PACS system | |
10. Interface | |
2*USB; 1*Video; 1*S-Video; 1*RJ-45; 1*HDMI; 1*DVI | |
11. Configuration | |
11.1 Full Digital Veterinary Color Doppler Ultrasound Diagnostic System | |
11.2 Probe (optional) : R11 micro-convex probe, Convex probe, Linear probe, Rectal probe | |
11.3 Video printer (optional), Trolley (optional) | |
11.4 Two Years Warranty for Main Unit and Probe against all manufacturing defects | |
11.5 Lifelong maintenance after warranty, lifelong free for software update | |
1. Product name: Veterinary Color Doppler Ultrasound System | |
1.1 Main structure: Laptop type | |
2. Applications | |
2.1 Suitable for ultrasound examination for various needs in pet hospitals, clinics, zoos, | |
breeding/breeding bases and various research units. | |
3.Main Specifications And System Overview | |
3.1 Operating system: Windows 10 operating system | |
3.2 Spectral pulse Doppler | |
3.3 Directional energy Doppler | |
3.4 Real-time triplex | |
3.5 Spatial composite imaging function | |
3.6 Tissue harmonic imaging technology(THI) | |
3.7 2B/4B imaging mode | |
3.8 System language option: Chinese, English, French, Russian, Spanish | |
3.9 Monitor: ≥ 15 inches | |
3.10 Integrated clipboard: shows saved images at the bottom of the screen, which can be directly | |
dumped or deleted DAWEI VETERINARY MEDICAL (JIANGSU) CO. ,LTD. | |
3.11 The system has the function of on-the-spot upgrade. | |
3.12 Preset conditions: for different inspections, preset inspection conditions for optimizing images, | |
reducing adjustments during operation, and external adjustments and combinations of adjustments | |
required for common use | |
3.13 Probe interface ≥ 1 | |
3.14 Trapezoidal imaging function | |
3.15 One-click intelligent optimization | |
4. Probes | |
Line array probe (7.5MHz): frequency: | |
6.0MHz/7.5MHz/8.5MHz/10.0MHz/12.0MHz/H10.0MHz,six-segment frequency conversion (depth | |
20-128MM) | |
Micro-convex probe (R11) (6.5MHz): frequency | |
4.5MHz/5.0MHz/6.0MHz/6.5MHz/7.0MHz/9.0MHz/H8.0Mhz, seven-segment frequency conversion | |
(depth 30-111MM) | |
Micro-convex probe (R15) (6.0MHz): frequency | |
4.5MHz/5.0MHz/6.0MHz/6.5MHz/7.0MHz/9.0MHz/H8.0Mhz, seven-segment frequency conversion | |
(depth 30-111MM) | |
Convex array probe (3.5MHz): frequency | |
2.0MHz/2.5MHz/3.0MHz/3.5MHz/4.0MHz/5.5MHz/H4.0MHz/H5.0MHz,eight-segment frequency | |
conversion (depth 30-255MM) | |
Rectal probe (6.0MHz): frequency 4.0MHz/6.5MHz/9.0MHz/H8.0Mhz, four frequency bands (depth | |
20-110MM) | |
5 2D Imaging Mode | |
5.1 Gain: 0-100, step 1 visually adjustable | |
5.2 TGC: 8 segments adjustable | |
5.3 Dynamic range: 20-280dB 20 levels visually adjustable | |
5.4 Pseudo-color: 0-11 levels, visually adjustable | |
5.5 Sound power: 5%-100%, in 5% steps, visually adjustable | |
5.6 Postural markers ≥ 18 kinds | |
5.7 Maximum number of focus points: 6 focus points, can be moved throughout | |
5.8 gray scale: 0-7 levels of visual visibility adjustable | |
5.9 Filtering: 0-4 | |
5.10 Scan range: 50%-100% | |
5.11 Frame correlation: 0-4 levels, visually adjustable | |
5.12 screen with Chinese form real-time display acoustic power, probe frequency, dynamic range, | |
pseudo-color, gray scale and other 14 kinds of parameters can be adjusted | |
5.13 Scan line density: high school low | |
5.14 Noise reduction: 0-14 | |
6. Color Doppler Imaging Mode | |
6.1 Color frame correlation: 0-12 levels, visually adjustable | |
6.2 Color mapping: 0-7 levels, visually adjustable | |
6.3 Color flip: adjustable | |
6.4 B/C split screen synchronous display function: with | |
6.5 Color baseline: 11 levels, visually adjustable | |
6.6 Color line density: high and low adjustable | |
6.7 Wall filtering: 0-5 levels adjustable | |
7 Spectral Doppler Imaging Mode | |
7.1 Sampling volume angle correction: -80°~80°adjustable | |
7.2 Sampling volume: 0.5mm-20mm visually adjustable | |
7.3 Frequency: 2.5MHz and 3.0Mhz etc. visually adjustable (different probe range) | |
7.4 Baseline: 11 levels adjustable | |
7.5 Pseudo-color spectrum: 0-5 | |
7.6 display layout: ≥ 4 kinds of visual adjustable | |
7.7 Speed scale: 32.8-328cm / s (different probe range) | |
7.8 Spectrum envelope function: real-time automatic spectrum envelope, manual spectrum envelope | |
and other modes can be selected, the system automatically analyzes and displays: PS, ED, PI, RI, S/D,HR and other data | |
7.9 Gray scale: 0-7 | |
7.10 Wall filtering: 0-8 | |
7.11 Dynamic range: 10-90db step by step 5 | |
7.12 Noise reduction: 0-60 | |
7.13 Volume: 0-100 | |
8 Measurement And Analysis Functions | |
8.1 Measurement items include distance, area, angle, time, slope, heart rate, speed, acceleration, | |
resistance index/beat index and other specialized measurements | |
8.2 Having specialized measurement kits according to the different organs examined. | |
8.3 Measurement line color, line type can be adjusted (including activation color and completion color) | |
8.4 The position and font size of the measurement result display can be adjusted as required. | |
8.5 Specialized software packages: obstetrics, hepatobiliary, renal, bladder, cardiac, gastrointestinal, | |
uterine, adrenal, pancreatic, vascular, etc. | |
9 Graphic Management System: picture saving format: BMP DCM JPG | |
9.1 host built-in ≥ 128G solid-state drive start fast and stable | |
9.2 Movie playback: ≥ 600 frames | |
9.3 Built-in Chinese file information management system: can record the number ID, pet nickname, pet | |
NO., owner's name, etc., and can search and manage by number ID, pet nickname, pet NO., owner's | |
name, etc. | |
9.4 Report type ≥ 6, abdominal ultrasound report, cardiac ultrasound report, obstetric ultrasound report, | |
small organ ultrasound report, urological ultrasound report, vascular ultrasound report, provide picture | |
proof. | |
9.5 Quick report graphic management | |
9.6 With DICOM 3.0 protocol, can connect to PACS system | |
10 Interfaces | |
4 USB ports, 1 Audio, 1 HDMI, 2 RJ-45. | |
11 Configuration | |
11.1 Color Doppler ultrasound diagnostic system Mainframe 1 set | |
11.2 Probes : Micro-convex R11 probe (standard), line array probe (optional), rectal probe (optional), | |
etc. | |
11.3 Video printer (optional), ultrasound medical cart (optional) |
Packaging
1. Internal packaging: Initially, Our flat-panel detector is meticulously encased in moisture-resistant paper or plastic film and then securely nestled within a robust foam or custom-shaped foam mold. This carefully orchestrated layering ensures the equipment's unwavering stability throughout the entire transportation journey, guaranteeing it arrives in pristine condition.
2. Buffer layer: Envelop the flat-panel detector with a substantial layer of cushioning materials like foam and bubble film. This added layer acts as an impenetrable shield against external shocks, vigilantly safeguarding the machinery's integrity at every turn.
3. Flat-panel detector outer box packaging: Enclose the internally packaged equipment within a sturdy outer box. Constructed from multi-layer corrugated cardboard, this outer shell offers exceptional compression and impact resistance, fortifying its contents against unexpected impacts and ensuring their unyielding protection.
4. Flat-panel detector box sealing fixed: Utilize high-strength tape or resilient packing belts to securely seal the outer box. This crucial step ensures the box remains impervious to accidental opening during transit, steadfastly maintaining its protective role until it reaches the final destination.
5. Transport identification: Clearly display transport labels on the outer box, prominently featuring essential handling instructions such as 'fragile,' 'this end up,' and 'handle with care.' These indicators guide handlers in exercising the utmost diligence and care during each transport phase.
Shipping
Shipping: During Our flat-panel detector transport, we meticulously select the most optimal transport modes and routes to minimize exposure to severe vibrations and turbulence. For extended distances, we favor containers or specially designed transport vehicles offering superior earthquake resistance. Customers can choose from air, sea, land, or rail transport based on their specific needs, ensuring a tailor-made solution that aligns seamlessly with their requirements.
Q1. What is our main product?
A1: We are the original manufacturer of X- ray machine and accessories. Our main products are Mobile X-ray machine, X-ray Detector, etc.